Continental Hydraulics PowrFlow™ PVX Vane Pumps deliver the rugged, reliable performance and value you've come to expect in all our products. They outperform sensitive piston pumps in harsh enviroments. PVX Vane Pumps deliver faster response, and require less external compensation compared to fixed displacement designs. The pumps are designed to meet requirements of the machine tool, general machinery and other markets where low noise, high performance and competitive pricing are needed.
Description | Units |
---|---|
Displacement (Nominal) | 2 in³/rev (32 cm³/rev) |
Displacement (Actual) | 2.04 in³/rev (32 cm³/rev) |
Flow at 1750 RPM | 15.15 gpm (57.3 l/min) |
Maximum Continuous Pressure | 3000 PSI (210 bar) |
Pressure Compensating Range Single Stage | 200 - 3000 psi (14 - 210 bar) / Minimum 290 PSI (19 Bar) |
Pressure Compensating Range Two Stage | 300 - 3000 psi (21 - 210 bar ) / Minimum 290 psi (19 bar) |
Maximum Transient Spike Pressure | 4000 psi (280 bar) |
Maximum Case Pressure | 10 psi (0.7 bar) |
Speed Range | 1150 - 1800 rpm |
Direction of Rotation (viewed shaft end) | Right hand (clockwise) |
Case drain flow while compensating at 1800 rpm 1000 psi (70 bar) | 0.6 gpm (2.3 l/min) |
Case drain flow while compensating at 1800 rpm 2000 psi (140 bar) | 1.1 gpm ( 4.2 l/min) |
Case drain flow while compensating at 1800 rpm 3000 psi (210 bar) | 1.4 gpm (5.3 l/min) |
Maximum inlet vacuum at sea level | 6 inches Hg (152mm Hg) |
Mounting - SAE 2 bolt flange (ISO 3019/1) | S.A.E 'B' - 2 bolt flange |
Mounting Position | Unrestricted |
Inlet Port Size | #24 S.A.E |
Outlet Port Size | #16 S.A.E |
Case Drain Port Size | #8 S.A.E |
Clipper Control Drain Port Size | #6 S.A.E |
Remote Control Port Size | #4 S.A.E |
Minimum Fluid Viscosity at Operating Temperature | 100 SUS (21 cSt) |
Maximum Fluid Viscosity at Operating Temperature | 1000 SUS (216 cSt) |
Optimum Fluid Viscosity at Operating Temperature | 150-250 SUS (32-54 cSt) |
Maximum Start-Up Maximum Fluid Viscosity at Operating Temperature | 4000 SUS (21 cSt) |
Response time (Circuit dependent) Full Flow to Minimum flow | 20 - 35 ms |
Response time (Circuit dependent) Minimum flow to full flow | 70 - 185 ms Single Stage Compensator |
Single Stage Weight | 61 lbs (27.7 kg) |
Two Stage Weight | 65 lbs (29.43 kg) |
Vat Reg Number: 846644204 Company Registration Number: 5230249