Frame mounted, 3 phase, 400v version of the SUT - Mounts directly to a larger oil reservoir to permit installation of a vertical solenoid valve subplate and return filter arrangement.
There are 3 base models for the 40 Series available:
The above models are all available with the following 3 configurations:
The innovative SUPERUNIT hybrid units represent the culmination of Daikin Industries LTD's design and manufacturing expertise. These units seamlessly integrate hydraulic technology with an internal permanent magnet synchronous motor, resulting in a powerful unit that excels in both torque and efficiency, all while effectively mitigating heat and noise production. This remarkable combination substantially reduces energy consumption.
The motor-pump's exceptional efficiency ensures minimal oil heating, which brings several advantages to the application in which the SUT is installed. This includes prolonged lifespan for oil and heat-sensitive components, as well as reduced heat dissipation into the surrounding environment.
In SUT models that are equipped with a double pump, the primary pump delivers high pressure and limited flow. When the flow rate request is higher than the flow rate that the primary pump can supply, the second pump is also activated, guaranteeing the required flow (at lower pressure). The transition from single to combined operation is done by a solenoid valve, managed by an external command signal.
For price and delivery on a Daikin Super Unit, please contact our sales team by email, sales@zeushydratech.com or Tel: +44(0)1172 130042
SUT00S3016 | SUT00D6021 | SUT00D8021 | ||||
---|---|---|---|---|---|---|
Identification Code | Q | Q100 | Q | Q100 | Q | Q100 |
Maximum operating pressure (bar) | 160 | 210 | 210 | |||
Operating pressure range - 1st pump (HP) - 1st + 2nd pump (HP+LP) |
5~ 60 - |
5~210 5~70 |
5~210 5~70 |
|||
Operating flow range (theoretical) - 1st pump (HP) - 1st + 2nd pump (HP+LP) |
3.5 ~24.3 - |
3.1~21.2 5~70 |
4.1~28.7 11.6~82 |
|||
Tank capacity | - | 100 | - | 100 | - | 100 |
Main Supply voltage (V) | 3 Phase, AC 380 ~ 460 Volts, 50/60Hz ± 10% | |||||
Controller Supply Voltage (V) | - | 24V DC (min 50 W) | ||||
Nominal motor power (KW) | 3.0 | 3.0 | 4.0 | |||
Rated Current (A) | 9.3 | 10.3 | 14.1 | |||
Fluid temperature range in tank (°C) | 0 to +60 (recommended +15 to +50) | |||||
Noise level range (dB) (Distance 1 metre) - 1st pump (HP) - 1st + 2nd pump (HP+LP) |
DH (160 bar) 52 dBA 25.6 l/min (20 bar) 70 dBA |
DH (210 bar) 57 dBA 61.1 l/min (20 bar) 74 dBA |
DH (210 bar) 57 dBA 83 l/min (20 bar) 77 dBA |
|||
Weight: (KG) - Without Tank - 100 - 100M* |
56 - - |
- 126 132 |
62 - - |
- 133 148 |
76 - - |
- 147 164 |
Awaiting video