Daikin's Super Unit has turned the conventional industrial hydraulic power pack on its head and made it into something very special indeed.
We live in a world that demands significant reductions in energy consumption. Conventional hydraulic power pack units utilised within industrial applications unnecessarily consume large amounts energy due to the nature of their design and configuration.
Daikin utilise their high efficiency interior permanent magnet (IPM) motor technology (previously pioneered and utilised in their successful air conditioning units) to give a variable speed drive solution to their hydraulic power pack. IPM motors operate at a 93% efficiency which is considerably more efficient than a conventional induction motor (typically 70-80%) In addition to their efficiency, IPM motors also give huge improvements in torque output during their required operating RPM, this results in a consistent pressure output from the hydraulic gear pump even at varying flow demands.
Daikin offer a broad range of Super Units to choose from (14 models in total)
Flow range: 15 ~ 110 litres/minute.
Operating pressure range: 70 ~ 206 bar
We carry a broad range of spares for the Daikin Super Unit so if you either wish to repair your unit yourself or would like us to do it for you, we're able to assit. Please call +44(0)1172 130042 or Email with your Super Unit part number and serial number to discuss your requirements.
Tankless type
Super unit - Part Number: | SUT00S1507-30 | SUT00S3007-30 | SUT00S4007-30 | SUT00S6007-30 | SUT00S8007-30 | SUT00S11007-30 | |
---|---|---|---|---|---|---|---|
Pump unit | Max flow rate (theoretical value l/min) | 15.2 | 28.5 | 39.7 | 61.1 | 83.0 | 110 |
Max operating pressure (Bar) | 70 | 70 | 70 | 70 | 70 | 70 | |
Operating flow rate adjustment range l/min | 2.5 ~ 15.2 | 3.5 ~ 28.5 | 5.3 ~ 39.7 | 8.7 ~ 61.1 | 11.6 ~ 83.0 | 13.3 ~ 110 | |
Operating pressure adjustment range (Bar) | 15 ~ 70 | 15 ~ 70 | 15 ~ 70 | 1.5 ~ 70 | 15 ~ 70 | 15 ~ 70 | |
Motor capacity | Motor capacity (equivelant KW) | Equivelant to 2.2 KW | Equivelant to 2.8 KW | Equivelant to 3.7 KW | Equivelant to 5.0 KW | Equivelant to 7.0 KW | Equivelant to 11.0 KW |
Power supply | Motor/pump unit | 3-phase, 200V (50Hz), 200V (60Hz), 220V (60Hz) (Permissable voltage function +/- 10%) | |||||
Rated current (A) | AC3 200V (50Hz) | 11.5 | 15.4 | 16.1 | 22.1 | 25.5 | 38.3 |
AC3 200V (60Hz) | 11.3 | 15.1 | 15.8 | 21.7 | 24.8 | 37.8 | |
AC3 220V (60Hz) | 10.6 | 13.8 | 14.8 | 20.2 | 22.7 | 34.9 | |
Power source breaker setting (A) | 15 | 20 | 20 | 30 | 50 | 75 | |
External Input signal | 5 channels | ||||||
Photo-coupler insulation, DC 24V (DC 27V maximum), 5 mA/channel | |||||||
External output signal | Digital output | 2 channels, photo coupler insulation, FET output, DC 24V, 50mA maximum per channel | |||||
Contact output | 1 channel (1 common contact), dry contact. Contact capacity: DC30V, 0.5A (resistance load) | ||||||
Mass (kg) | 37 | 39 | 46 | 56 | 72 | 112 | |
Operating conditions | Useable oil | Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil. Viscosity grade: ISO VG32 to 68. Viscosity range: 15 to 400 mm2/s. Contamination: Within NAS class 10. Volumetric water content: 0.1% maximum | |||||
Operating hydraulic oil temp (in tank) | 0 - 60°C (Recommended operating temperature range: 15 ~ 50°C) | ||||||
Operating ambient temp | 0 ~ 40°C | ||||||
Storage ambient temp | -20 ~ 60°C | ||||||
Operating ambient humbidity | 85% RH max. (No condensation) | ||||||
Installation site | Indoors (Be sure to secure the unit with bolts) | ||||||
Other details | 1: Be sure to connect a circuit breaker for all 3 poles and the earth leakage breaker. | ||||||
2: Make sure that the electrical wiring meets the requirement of European Standard EN60204-1 | |||||||
3: Frequently turning the power supply off to the Super unit will shorten the service life - avoid where possible | |||||||
4: Be sure to connect the ground terminal | |||||||
Tank capacity (litres) | N/A | N/A | N/A | N/A | N/A | N/A | |
Standard coating colour |
Ivory white (Munsell code: 5Y7. 5/1) |
Super unit - Part Number: | SUT00S1510-30 | SUT00S3010-30 | SUT00S1516-30 | SUT00S3016-30 | SUT0000D4016-30 | SUT00D6021-30 | |
---|---|---|---|---|---|---|---|
Pump unit | Max flow rate (theoretical value l/min) | 15.2 | 25.6 | 15.2 | 25.6 | 41.0 | 61.1 |
Max operating pressure (Bar) | 100 | 100 | 160 | 160 | 157 | 206 | |
Operating flow rate adjustment range l/min | 2.5 ~ 15.2 | 3.4 ~ 25.6 | 2.4 ~ 15.2 | 3.4 ~ 25.6 | 5.4 ~ 41.0 | 8.7 ~ 61.1 | |
Operating pressure adjustment range (Bar) | 25 ~ 150 | 15 ~ 100 | 15 ~ 160 | 1.5 ~ 160 | 15 ~ 157 | 15~ 206 | |
Motor capacity | Motor capacity (equivelant KW) | Equivelant to 2.8 KW | Equivelant to 3.7 KW | Equivelant to 3.7 KW | Equivelant to 5.0 KW | Equivelant to 3.7 KW | Equivelant to 5.0 KW |
Power supply | Motor/pump unit | 3-phase, 200V (50Hz), 200V (60Hz), 220V (60Hz) (Permissable voltage function +/- 10%) | |||||
Rated current (A) | AC3 200V (50Hz) | 8.0 | 18.4 | 16.1 | 21.4 | 17.9 | 22.1 |
AC3 200V (60Hz) | 7.8 | 18.4 | 15.8 | 21.4 | 17.7 | 21.7 | |
AC3 220V (60Hz) | 7.5 | 16.9 | 14.8 | 20.2 | 16.5 | 20.2 | |
Power source breaker setting (A) | 15 | 20 | 20 | 30 | 20 | 30 | |
External Input signal | 5 channels | ||||||
Photo-coupler insulation, DC 24V (DC 27V maximum), 5 mA/channel | |||||||
External output signal | Digital output | 2 channels, photo coupler insulation, FET output, DC 24V, 50mA maximum per channel | |||||
Contact output | 1 channel (1 common contact), dry contact. Contact capacity: DC30V, 0.5A (resistance load) | ||||||
Mass (kg) | 39 | 46 | 46 | 52 | 53 | 58 | |
Operating conditions | Useable oil | Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil. Viscosity grade: ISO VG32 to 68. Viscosity range: 15 to 400 mm2/s. Contamination: Within NAS class 10. Volumetric water content: 0.1% maximum | |||||
Operating hydraulic oil temp (in tank) | 0 - 60°C (Recommended operating temperature range: 15 ~ 50°C) | ||||||
Operating ambient temp | 0 ~ 40°C | ||||||
Storage ambient temp | -20 ~ 60°C | ||||||
Operating ambient humbidity | 85% RH max. (No condensation) | ||||||
Installation site | Indoors (Be sure to secure the unit with bolts) | ||||||
Other details | 1: Be sure to connect a circuit breaker for all 3 poles and the earth leakage breaker. | ||||||
2: Make sure that the electrical wiring meets the requirement of European Standard EN60204-1 | |||||||
3: Frequently turning the power supply off to the Super unit will shorten the service life - avoid where possible | |||||||
4: Be sure to connect the ground terminal | |||||||
Tank capacity (litres) | N/A | N/A | N/A | N/A | N/A | N/A | |
Standard coating colour | Ivory white (Munsell code: 5Y7. 5/1) |
Unit type (Complete with oil tank)
Super unit - Part Number: | SUT03S1507-30 | SUT03S3007-30 | SUT03S4007-30 | SUT06S6007-30 | SUT10S8007-30 | SUT03S1510-30 | |
---|---|---|---|---|---|---|---|
Pump unit | Max flow rate (theoretical value l/min) | 15.2 | 28.5 | 39.7 | 61.1 | 83.0 | 15.2 |
Max operating pressure (Bar) | 70 | 70 | 70 | 70 | 70 | 100 | |
Operating flow rate adjustment range l/min | 2.5 ~ 15.2 | 3.5 ~ 28.5 | 5.3 ~ 39.7 | 8.7 ~ 61.1 | 11.6 ~ 83.0 | 2.5 ~ 15.2 | |
Operating pressure adjustment range (Bar) | 15 ~ 70 | 15 ~ 70 | 15 ~ 170 | 1.5 ~ 70 | 15 ~ 70 | 15~ 100 | |
Motor capacity | Motor capacity (equivelant KW) | Equivelant to 2.2 KW | Equivelant to 2.8 KW | Equivelant to 3.7 KW | Equivelant to 5.0 KW | Equivelant to 7.0 KW | Equivelant to 2.8 KW |
Power supply | Motor/pump unit | 3-phase, 200V (50Hz), 200V (60Hz), 220V (60Hz) (Permissable voltage function +/- 10%) | |||||
Rated current (A) | AC3 200V (50Hz) | 11.5 | 15.4 | 16.1 | 22.1 | 25.5 | 8.0 |
AC3 200V (60Hz) | 11.3 | 15.1 | 15.8 | 21.7 | 24.8 | 7.8 | |
AC3 220V (60Hz) | 10.6 | 13.8 | 14.8 | 20.2 | 22.7 | 7.5 | |
Power source breaker setting (A) | 15 | 20 | 20 | 30 | 50 | 15 | |
External Input signal | 5 channels | ||||||
Photo-coupler insulation, DC 24V (DC 27V maximum), 5 mA/channel | |||||||
External output signal | Digital output | 2 channels, photo coupler insulation, FET output, DC 24V, 50mA maximum per channel | |||||
Contact output | 1 channel (1 common contact), dry contact. Contact capacity: DC30V, 0.5A (resistance load) | ||||||
Mass (kg) | 59 | 59 | 64 | 97 | 131 | 59 | |
Operating conditions | Useable oil | Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil. Viscosity grade: ISO VG32 to 68. Viscosity range: 15 to 400 mm2/s. Contamination: Within NAS class 10. Volumetric water content: 0.1% maximum | |||||
Operating hydraulic oil temp (in tank) | 0 - 60°C (Recommended operating temperature range: 15 ~ 50°C) | ||||||
Operating ambient temp | 0 ~ 40°C | ||||||
Storage ambient temp | -20 ~ 60°C | ||||||
Operating ambient humbidity | 85% RH max. (No condensation) | ||||||
Installation site | Indoors (Be sure to secure the unit with bolts) | ||||||
Other details | 1: Be sure to connect a circuit breaker for all 3 poles and the earth leakage breaker. | ||||||
2: Make sure that the electrical wiring meets the requirement of European Standard EN60204-1 | |||||||
3: Frequently turning the power supply off to the Super unit will shorten the service life - avoid where possible | |||||||
4: Be sure to connect the ground terminal | |||||||
Tank capacity (litres) | 30 | 30 | 30 | 60 | 100 | 30 | |
Standard coating colour | Ivory white (Munsell code: 5Y7. 5/1) |
Super unit - Part Number: | SUT03S3010-30 | SUT03S1516-30 | SUT06S3016-30 | SUT06D4016-30 | SUT06D6021-30 | SUT10D6021-30 | |
---|---|---|---|---|---|---|---|
Pump unit | Max flow rate (theoretical value l/min) | 25.6 | 15.2 | 25.6 | 41.0 | 61.1 | 61.1 |
Max operating pressure (Bar) | 100 | 160 | 160 | 157 | 206 | 206 | |
Operating flow rate adjustment range l/min | 3.4 ~ 25.6 | 2.4 ~ 15.2 | 3.4 ~ 25.6 | 5.4 ~ 41.0 | 8.7 ~ 61.1 | 8.7 ~ 61.1 | |
Operating pressure adjustment range (Bar) | 15 ~ 100 | 15 ~ 160 | 15 ~ 160 | 1.5 ~ 157 | 15 ~ 206 | 15~ 206 | |
Motor capacity | Motor capacity (equivelant KW) | Equivelant to 3.7 KW | Equivelant to 3.7 KW | Equivelant to 5.0 KW | Equivelant to 3.7 KW | Equivelant to 5.0 KW | Equivelant to 5.0 KW |
Power supply | Motor/pump unit | 3-phase, 200V (50Hz), 200V (60Hz), 220V (60Hz) (Permissable voltage function +/- 10%) | |||||
Rated current (A) | AC3 200V (50Hz) | 18.4 | 15.2 | 21.4 | 17.9 | 22.1 | 22.1 |
AC3 200V (60Hz) | 18.4 | 15.2 | 21.4 | 17.7 | 21.7 | 21.7 | |
AC3 220V (60Hz) | 16.9 | 14.6 | 20.2 | 16.5 | 20.2 | 20.2 | |
Power source breaker setting (A) | 20 | 20 | 30 | 20 | 30 | 30 | |
External Input signal | 5 channels | ||||||
Photo-coupler insulation, DC 24V (DC 27V maximum), 5 mA/channel | |||||||
External output signal | Digital output | 2 channels, photo coupler insulation, FET output, DC 24V, 50mA maximum per channel | |||||
Contact output | 1 channel (1 common contact), dry contact. Contact capacity: DC30V, 0.5A (resistance load) | ||||||
Mass (kg) | 64 | 64 | 83 | 94 | 99 | 112 | |
Operating conditions | Useable oil | Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil. Viscosity grade: ISO VG32 to 68. Viscosity range: 15 to 400 mm2/s. Contamination: Within NAS class 10. Volumetric water content: 0.1% maximum | |||||
Operating hydraulic oil temp (in tank) | 0 - 60°C (Recommended operating temperature range: 15 ~ 50°C) | ||||||
Operating ambient temp | 0 ~ 40°C | ||||||
Storage ambient temp | -20 ~ 60°C | ||||||
Operating ambient humbidity | 85% RH max. (No condensation) | ||||||
Installation site | Indoors (Be sure to secure the unit with bolts) | ||||||
Other details | 1: Be sure to connect a circuit breaker for all 3 poles and the earth leakage breaker. | ||||||
2: Make sure that the electrical wiring meets the requirement of European Standard EN60204-1 | |||||||
3: Frequently turning the power supply off to the Super unit will shorten the service life - avoid where possible | |||||||
4: Be sure to connect the ground terminal | |||||||
Tank capacity (litres) | 30 | 30 | 60 | 60 | 60 | 100 | |
Standard coating colour | Ivory white (Munsell code: 5Y7. 5/1) |
Super unit - Part Number: | SUT10D8021-30 | SUT16D8021-30 | P-SUT20D11KW-30 | SUT00D8021-30 | SUT00D11021-30 | |
---|---|---|---|---|---|---|
Pump unit | Max flow rate (theoretical value l/min) | 83.0 | 183.0 | 110 | 83.0 | 110 |
Max operating pressure (Bar) | 206 | 206 | 206 | 206 | 206 | |
Operating flow rate adjustment range l/min | 11.6 ~ 83.0 | 11.6 ~ 83.0 | 13.3 ~ 110 | 11.6 ~ 83.0 | 13.3 ~ 110 | |
Operating pressure adjustment range (Bar) | 15 ~ 206 | 15 ~ 206 | 15 ~ 206 | 1.5 ~ 206 | 15 ~ 206 | |
Motor capacity | Motor capacity (equivelant KW) | Equivelant to 7.0 KW | Equivelant to 7.0 KW | Equivelant to 11.0 KW | Equivelant to 7.0 KW | Equivelant to 11.0 KW |
Power supply | Motor/pump unit | 3-phase, 200V (50Hz), 200V (60Hz), 220V (60Hz) (Permissable voltage function +/- 10%) | ||||
Rated current (A) | AC3 200V (50Hz) | 25.5 | 25.5 | 38.3 | 25.5 | 38.3 |
AC3 200V (60Hz) | 24.8 | 24.8 | 37.8 | 24.8 | 37.8 | |
AC3 220V (60Hz) | 22.7 | 22.7 | 34.9 | 22.7 | 34.9 | |
Power source breaker setting (A) | 50 | 50 | 75 | 50 | 75 | |
External Input signal | 5 channels | |||||
Photo-coupler insulation, DC 24V (DC 27V maximum), 5 mA/channel | ||||||
External output signal | Digital output | 2 channels, photo coupler insulation, FET output, DC 24V, 50mA maximum per channel | ||||
Contact output | 1 channel (1 common contact), dry contact. Contact capacity: DC30V, 0.5A (resistance load) | |||||
Mass (kg) | 133 | 145 | 360 | 72 | 112 | |
Operating conditions | Useable oil | Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil. Viscosity grade: ISO VG32 to 68. Viscosity range: 15 to 400 mm2/s. Contamination: Within NAS class 10. Volumetric water content: 0.1% maximum | ||||
Operating hydraulic oil temp (in tank) | 0 - 60°C (Recommended operating temperature range: 15 ~ 50°C) | |||||
Operating ambient temp | 0 ~ 40°C | |||||
Storage ambient temp | -20 ~ 60°C | |||||
Operating ambient humbidity | 85% RH max. (No condensation) | |||||
Installation site | Indoors (Be sure to secure the unit with bolts) | |||||
Other details | 1: Be sure to connect a circuit breaker for all 3 poles and the earth leakage breaker. | |||||
2: Make sure that the electrical wiring meets the requirement of European Standard EN60204-1 | ||||||
3: Frequently turning the power supply off to the Super unit will shorten the service life - avoid where possible | ||||||
4: Be sure to connect the ground terminal | ||||||
Tank capacity (litres) | 100 | 160 | 200 | Tankless model | Tankless model | |
Standard coating colour | Ivory white (Munsell code: 5Y7. 5/1) |
Awaiting video